Step 1. Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2. (Optional) If you are replacing the integrated diagnostics panel, insert the diagnostics panel into the
front I/O module. Ensure that the panel is fully seated into the assembly.
Figure 80. Installing the integrated diagnostics panel
Step 3. Install the front I/O module.
Figure 81. Front I/O module with the front operator
panel
Figure 82. Front I/O module with the integrated
diagnostics panel
a.
Insert the front I/O module into the front chassis.
b.
Install the screw to secure the front I/O module in place.
After you finish
1. Connect the cables of the front I/O module to the system board assembly. See Chapter 6 “Internal cable
routing” on page 281.