Table 29. LEDs description (continued)
Scenario
AP0 
LED
AP1 
LED 
Fatal 
Error 
LED
FPGA 
heartbeat 
LED
note
XCC 
heartbeat 
LED
note
Actions
No system power 
(FPGA heartbeat 
LED off)
Off Off Off Off Off If the AC power is on, but the 
system board assembly does 
not have power, then: 
1.  Check the power supply 
unit (PSU) or power 
interposer board (PIB) if 
any. If the PSU or PIB has 
any error, replace it.
2.  If the PSU or PIB is good, 
do the following:
a.  Replace the system I/O 
board.
b.  Replace the processor 
board.
XCC firmware 
recoverable error
Blink
N/A Off N/A N/A Information only. No action is 
required.
XCC firmware is 
recovered from 
error
Blink
N/A Off N/A N/A Information only. No action is 
required.
UEFI firmware 
authentication 
failure
N/A
Blink
Off N/A N/A Information only. No action is 
required.
UEFI firmware is 
recovered from 
authentication 
failure
N/A On Off N/A N/A Information only. No action is 
required.
System is OK 
(FPGA heartbeat 
LED is On)
On On Off On On Information only. No action is 
required.
Note: For locations of the FPGA LED and XCC heartbeat LED, see 
“System-board-assembly LEDs” on page 
493
.
General problem determination procedures
Use the information in this section to resolve problems if the event log does not contain specific errors or the 
server is inoperative.
If you are not sure about the cause of a problem and the power supplies are working correctly, complete the 
following steps to attempt to resolve the problem: 
1.  Power off the server.
2.  Make sure that the server is cabled correctly.
3.  Remove or disconnect the following devices if applicable, one at a time, until you find the failure. Power 
on and configure the server each time you remove or disconnect a device. 
•  Any external devices.
•  Surge-suppressor device (on the server). 
•  Printer, mouse, and non-Lenovo devices.
496
ThinkSystem SR665 V3 User Guide