Front 
bays
Max. 
Tem-
p.
Processor
Heat 
sink
Air 
baffle
Fan 
type
Max. GPU Qty. Support 
DIMMs 
>= 96 
GB
SW
DW 
(A2000)
DW 
(A40)
DW 
(H100)
Other 
DW
8 x 
2.5"
30°C
Group B
2U S S P 10 3 NA NA NA Y
Group A
2U P S P 10 3
NA NA NA Y*
Group B, A
2U P GPU P NA NA
2 (slot 2/ 
5)
3 3 Y
16 x 
2.5"
30°C
Group B
2U S S P 10 3 NA NA NA Y
Group A
2U P S P 10 3
NA
NA
NA Y*
Group B, A
2U P GPU P NA NA
2 (slot 2/ 
5)
2 (slot 2/ 
5)
3 Y
8 x 
3.5"
30°C
Group B
2U S S P 10 3 NA NA NA Y
Group A
2U P S P 10 3
NA NA NA Y*
Group B, A
2U P GPU P NA NA 3 3 3 Y
8 x 
2.5"
16 x 
2.5"
8 x 
3.5"
25°C
Group B
2U S S P 6 3 NA NA NA Y
25°C
Group A, E
2U P S P 6 3 NA NA NA Y
25°C
Group B, 
A, E
2U P GPU P NA NA NA
2 (slot 2/ 
5)
2 (slot 2/ 
5)
Y
24 x 
2.5"
25°C
Group B
2U S S P 6 3 NA NA NA Y
Group A
2U P S P 6 3 NA NA NA Y*
Group B, A
2U P GPU P NA NA NA
2 (slot 2/ 
5)
2 (slot 2/ 
5)
Y*
Notes: 
•  Group E processors in the table above include 9654(P), 9554(P), 9174F, 9754, and 9734.
•  For GPU configurations, the Max. Temp. of 25°C is supported under the following conditions: 
–  A part with AOC and at a rate greater than 25 GB is not installed in slot 3.
–  The following parts are not installed:
–  Broadcom 57416 10GBASE-T 2-port OCP
–  Broadcom 57454 10GBASE-T 4-port OCP
Power on and power off the server
Follow instructions in this section to power on and power off the server.
Power on the server
After the server performs a short self-test (power status LED flashes quickly) when connected to input power, 
it enters a standby state (power status LED flashes once per second).
Power button location and power LED are specified in: 
Chapter 5. Hardware replacement procedures 61