Variable
Description
<m/t_model>
The server machine type and model number.
Type xxxxyyy, where xxxx is the machine type and yyy is the server model number.
<s/n>
The serial number on the server.
Type zzzzzzz, where zzzzzzz is the serial number.
<system model>
The system model on the server.
Type system yyyyyyyy, where yyyyyyyy is the product identifier.
<asset_tag>
The server asset tag number.
Type aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is 
the asset tag number.
[access_method]
The access method that you select to access the target server.
•  Online KCS (unauthenticated and user restricted): 
You can directly delete [access_method] from the command.
•  Online authenticated LAN:  
In this case, specify below LAN account information at the end of the OneCLI 
command:
--bmc-username <user_id> --bmc-password <password>
•  Remote WAN/LAN:  
In this case, specify below XCC account information and IP address at the end of the 
OneCLI command:
--bmc <bmc_user_id>:<bmc_password>@<bmc_external_IP> 
Notes: 
–  <bmc_user_id> 
The BMC account name (1 of 12 accounts). The default value is USERID.
–  <bmc_password> 
The BMC account password (1 of 12 accounts).
System fan replacement
Follow instructions in this section to remove and install a system fan.
• 
“Remove a system fan” on page 264
•  “Install a system fan” on page 266
Remove a system fan
Follow instructions in this section to remove a system fan. 
About this task
264 ThinkSystem SR665 V3 User Guide