Figure 96. Installing the internal CFF adapter
Step 3. Connect cables to the adapter. See Chapter 6 “Internal cable routing” on page 281.
After you finish
1. Install the system fan cage. See
“Install the system fan cage” on page 270.
2. Complete the parts replacement. See
“Complete the parts replacement” on page 279.
Demo video
Watch the procedure on YouTube
Intrusion switch replacement
Follow instructions in this section to remove and install the intrusion switch. The intrusion switch informs you
that the server cover is not properly installed or closed by creating an event in the system event log (SEL).
• “Remove the intrusion switch” on page 139
• “Install the intrusion switch” on page 141
Remove the intrusion switch
Follow instructions in this section to remove the intrusion switch.
About this task
Attention:
• Read
“Installation Guidelines” on page 47 and “Safety inspection checklist” on page 48 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 62.
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Chapter 5. Hardware replacement procedures 139