Lenovo ThinkSystem SR665 V3 - Management NIC Adapter Replacement; Remove the Management NIC Adapter

Lenovo ThinkSystem SR665 V3
540 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 115. Installing the memory module
a.
Gently open the retaining clip on each end of the memory module slot.
b.
Align the memory module with the slot, and gently place the memory module on the slot
with both hands.
c.
Firmly press both ends of the memory module straight down into the slot until the retaining
clips snap into the locked position.
After you finish
Complete the parts replacement. See
“Complete the parts replacement” on page 279.
Demo video
Watch the procedure on YouTube
Management NIC adapter replacement
Follow instructions in this section to remove and install the ThinkSystem V3 Management NIC Adapter Kit
(management NIC adapter).
Note: If the ThinkSystem V3 Management NIC Adapter Kit (management NIC adapter) is installed on the
server, it will not be displayed on the PCIe card list of system management software, such as XCC, LXPM,
and so on.
“Remove the management NIC adapter” on page 156
“Install the management NIC adapter” on page 158
Remove the management NIC adapter
Follow instructions in this section to remove the management NIC adapter.
About this task
Attention:
156 ThinkSystem SR665 V3 User Guide