S017
CAUTION:
Hazardous moving fan blades nearby. Keep fingers and other body parts away.
Attention:
Read
“Installation Guidelines” on page 47 and “Safety inspection checklist” on page 48 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 62.
Procedure
Note: The illustrated air baffle is the standard air baffle. The removal procedure is the same for the GPU air
baffle.
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 63.
b. Remove the top cover. See
“Remove the top cover” on page 277.
c. If there is a RAID flash power module installed on the air baffle, disconnect the cable of the
RAID flash power module.
d. If there is an M.2 drive installed on the air baffle, disconnect M.2 backplane cables from the
M.2 backplane.
e. If there is a GPU installed on the air baffle, remove the GPU. See
“Remove a GPU adapter” on
page 126
.
Step 2. Grasp the air baffle and carefully lift it out of the chassis.
Attention: For proper cooling and airflow, reinstall the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Chapter 5. Hardware replacement procedures 71