Linksys Voice System Administration Guide 36
Using the Interactive Voice Response Unit
Basic Administration of the SPA9000
Set Static Gateway
IP Address
131 Enter IP address using
numbers on the
telephone key pad. Use
the * (star) key when
entering a decimal
point.
DHCP must be “Disable,
otherwise you hear, “Invalid
Option,” if you try to set this
value.
Requires password
Check MAC
Address
140 None IVR announces the MAC address
of SPA in hex string format.
Check Firmware
Version
150 None IVR announces the version of the
firmware running on the SPA.
Check Primary
DNS Server
Setting
160 None IVR announces the current
setting in the <Primary DNS>
parameter.
Set Primary DNS
Server
161 Enter IP address using
numbers on the
telephone key pad. Use
the * (star) key when
entering a decimal
point.
Requires password
Check
administration
web server port
170 None IVR announces the port that the
web server is listening on.
(Default is 80)
Check LAN IP
Address
210 None IVR announces the current IP
address of the LAN port.
Check PBX
multicast address
180 None IVR announces the current value.
Set PBX multicast
address
181 Enter IP address and
port. Use * key for
entering a dot. For
example,
224.168.168.169:8089 is
224*168*168*169*8089.
Enter a * between the IP address
and the Port fields. Requires
Password
Enable/Disable
administration
web server
7932 Enter 1 to enable
Enter 0 to disable
Requires password
Manual Reboot of
Unit
732668 None After you hear “Option
Successful,” hang up. Unit
reboots automatically.
Table 2-1 IVR Options (Continued)

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms