NTP-016: System Turnup 363-206-285
Page 4 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
NOTE:
If fecom is enabled, an inconsistent DCC values alarm
will occur when the OLIUs are looped back. Normally, the
alarm occurs when the Network side/User side parameters
at both ends of the DCC are set the same. To clear the alarm
during a fiber loopback, use the
set-fecom:address:com=disable command to disable
the DCC.
DLP-505Install OLIU optical loops.
8.
NOTE:
BBG2/BBG2B MXRVO circuit packs must be installed in
both FUNCTION UNIT slots 1 and 2(P) if BBF3/BBF3B
DS1PM circuit packs are going to be installed.
DLP-506Install BBG2/BBG2B MXRVO circuit packs (if required).
DLP-5079. Install BBG4/BBG4B/BBG19 DS3 circuit packs (if required).
DLP-50710. Install BBG20 TMUX circuit packs (if required).
DLP-50211. Install BBG6 STS1E (optioned for LOW SPEED) circuit packs (if
required).
DLP-505
DLP-506
DLP-507
DLP-502

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals