NTP-016: System Turnup 363-206-285
Page 6 of 10 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
13.
NOTE:
A maximum of three BBF8 HDSL circuit packs, including a
protection circuit pack, can be installed in any one function
group. Both service and protection MXRVO circuit packs
must also be installed.
DLP-564Install BBF8 HDSL circuit packs (if required).
14.
NOTE:
Both service and protection MXRVO circuit packs must be
installed in FUNCTION UNITS groups corresponding to
LOW SPEED GROUP(s) equipped with T1EXT circuit packs.
DLP-517Install T1EXT circuit pack(s) (if required).
DLP-51815. Install BBF9/BBF10 IMA LAN circuit packs (if required).
16.
!
CAUTION:
The command
init-sys:all
may affect service. It should
never be used on an in-service system. It should be used
only after a shelf has been equipped to reset all
provisionable parameters and cross-connections to their
default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed because "fecom"
becomes enabled again. To clear the alarm, use the
set-fecom:address:com=disable to disable the DCC.
Use the init-sys:all command to initialize all provisionable
parameters to their original default values. It may take
approximately 2 minutes after init-sys:all command for
alarms to stabilize.
DLP-50917. Perform an LED test.
DLP-564
DLP-517
DLP-518
DLP-509