When an electrical charge accident occurred, do not panic and stay calm, apply the solution in the
following sequence.
1. Report
Immediately report to the electricity company or related management company, and receive
instructions for the power transmission stop, emergency procedures and related.
2. Evacuation of related personnel from vicinity of Machine
Let the related personnel including the workers from vicinity of the Machine to prevent secondary
disasters.
Personnel who suffered electrical shock by holding a sling rope, guide rope or other conductor when
the Machine was charged should evacuate by his/her own effort.
Do not try to help such person. Otherwise, secondary electrical shock accident can occur.
3. Emergency procedure
Take the solution by following sequence in case of urgency where personnel received electrical shock
because the Machine was charged.
(1) If the Machine can be operated, immediately operate the Machine to move the Machine
constructions away from the contact and out of the range of the cause of the charge. Be careful
not to snip the distribution power cable.
(2) Evacuate the Machine completely away from the cause of the charge, make sure the Machine is
not charged, rescue the electrically shocked personnel and immediately carry to the hospital.
4. Measure after accident
After accident, do not reuse as is. Such attempt may cause unexpected accidents and enhances
failures. Ask us or our sales service agency for repair.
Working with crane near high output microwave emission equipment such as a radar or TV/radio
broadcast antenna causes the crane construction to be exposed to the microwave and generates
induced current, therefore is very dangerous. In addition, the mechatronics may become disturbed.
Establish grounding between the Machine frame and the ground when working in such location. In
addition, slingers are requested to wear rubber boots and rubber gloves since risk of electrical shock by
contacting parts such as the hook or wire exists.
Inhalation air containing asbestos may result in lung cancer. This
Machine does not use any asbestos, but asbestos may be contained
in the wall, ceiling or other part of construction within the work area of
this Machine. In addition, be careful of the followings when working
with a material that may be using asbestos.
• Put on designated dust free mask and/or other equipment as
necessary.
• Do not use compressed air for cleaning.
• Spray water when cleaning to prevent asbestos dusts from flying
into air.
• Always work at windward location when driving the Machine at a
site that may contain asbestos dusts.
• Enforce keep out to prevent people from entering the working site.
• Strictly observe the assigned rules related to the working site and
environmental standard.