Parameter
Code Display Function Range Initial Value
Access
Level
D5-03 Speed Limit Sel Speed Limit Selection (See
figure below)
1-2 2 Adv
1 Analog Input
2 Program Setting
D5-04 Speed Lmt Value Speed Limit Value (% of
E1-04)
-120–120% 100 Adv
D5-05 Speed Lmt Bias Speed Limit Bias (% of
E1-04)
0–120% 0 Adv
D5-06 Ref Hold Time Speed/Torque Switching
Timer
0–1000 ms 0 Adv
Torque Reference
(from Terminal A2 or A3)
1
1+sT
d5-02
Torque
Reference