Level
O3-01 Flt Trace CLear Clears fault history 0 to 1 0 Adv
0 Not Clear
1 Clear U2/U3
O3-02 Count Hist Clear Clears count history. 0 to 3 0 Adv
0 Not Clear
1 AC Count Clr Clears AC operations (U3-09).
2 OL/LC Count Clr Clears OL/LC (U3-10).
3 Both Count Clr Clears Both (U3-09 and U3-10).
Parameter
Code Display Function Range
Initial
Value
Access
Level
O4-01 Copy Function Sel Copy parameters to/from keypad 0-3 0 Adv
0 Copy Select
1 Inv –> OP Read
2 OP –> Inv Write
3 OP <–> Inv Verify
O4-02 Read Allowable Enables/disables copy function 1 Adv
0 Disabled
1 Enabled