IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
6-20
Braking Circuit
Test Equipment - Analog Ohmmeter set to R X 1 scale or digital multimeter set to the diode check.
Figure 6-1
Step No.
Ohmmeter
Positive Lead
Ohmmeter
Negative Lead
Expected Reading
(Analog Meter)
Expected Reading
(Digital Meter)
1 Connect to B2 Connect to B1 10 Ohms 0.5 Volts
2 Connect to B1 Connect to B2 Infinite Ohms 0L displayed
3 Connect to B2 – Infinite Ohms 0L displayed
4 – Connect to B2 Infinite Ohms 0L displayed