IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-56
Motor 2 Set-up
Parameter
Code Display Function Range
Initial
Value
Access
Level
E4-01 Motor Rated FLA Motor-rated current for Motor 2 0.0–150.0 A * Adv
E4-02 Motor Rated Slip Motor-rated slip frequency for
Motor 2
0.00–20.0 Hz * Adv
E4-03 No Load Current Motor no-load current for Motor
2
0.0–150.0 A * Adv
E4-04 Number of Poles Number of poles in motor 2-48 * Adv
E4-05 Terminal Resistance Motor 2 Terminal Resistance 0.000–65.000Ω *Adv
E4-06 Leakage Inductance Leakage Inductance for Motor 2 0.0-40% * Adv
E4-07 Motor Rated Power Motor 2 Rated KW 0.40-650KW * Adv
* Values automatically set at Auto Tuning