IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-72
External Fault Response Selection
It is sometimes desirable to have at least one external fault input to the drive. To properly program a
multi-function input (H1-01 to H1-06) for this purpose an external fault response must be selected.
The table below shows the possible selections for an external fault response.
* Uses B5-08 timer
(1) N.O. = normally open contact; N.C. = normally closed contact
(2) Setting 24 is the factory default
Table 5-8:
External Fault Selection
Input Level
Selection Detection Method External Fault Action
MFI Setting
Result
N.O. N.C. Always
During
Run
Ramp to
Stop Coast to Stop Fast-stop*
Alarm
Only
√√ 20
√√ 24
√√ 28
√√ 2C
√√ 22
√√ 26
√√ 2A
√√ 2E
√√ 21
√√ 25
√√ 29
√√ 2D
√√ 23
√√ 27
√√ 2B
√√ 2F