IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-9
Motor Rotation Change
This parameter allows you to change the motor direction without changing the motor leads.
Zero-Speed Operation
This parameter sets the speed reference level at which Zero Speed mode operation will activate, in
accordance with the selection programmed B3-05 (see the figures below).
Parameter
Code Display Function Range
Initial
Value Access Level
B3-04 Reverse Oper Reverse motor direction 0-1 0 Adv
0 Normal Rotation
1 Exchange Phases
Parameter
Code
Display Function Range Initial
Value
Access Level
B3-05 Zero-Speed Oper Operation Selection at Zero
Speed.
0-3 0 Adv.
0 RUN at Freq Ref Operate according to the
Frequency Reference
1 Stop Coast when the Frequency
Reference is below E1-09
2 RUN at Min. Freq
(E1-09)
Output the Frequency set in
E1-09
3 RUN at Zero RPM