Parameter
Code Display Function Range
Initial
Value
Access
Level
L6-02 Torq Det 1 Lvl Sets the overtorque detection as
a percentage of inverter rated
current, during V/f control, and
motor rated torque during vector
control.
0–300% 150 Adv
L6-03 Torq Det 1 Time The overtorque detection delay
time inserts a delay, between the
time motor current (or torque)
exceeds the overtorque level
(L6-02) and when the overtorque
detection function is enabled.
The digital operator then
displays “OL3”.
0.0–10.0 sec 0.1 Adv