IMPULSE•VG+ Series 3 Instruction Manual - 07/25/05
3-7
4150 -FVG+S3 200 J 300 2/0 16/14 6
4180 -FVG+S3 250 J 350 3/0 16/14 4
4260 -FVG+S3 350 J 500 (2) 1/0 16/14 2
4304 -FVG+S3 400 J 600 (2) 2/0 16/14 2
4370 -FVG+S3 500 J 700 (2) 3/0 16/14 2
4477 -FVG+S3 700 L 900 (2) 250 KCMIL 16/14 1/0
4590 -FVG+S3 800 L 1000 (2) 300 KCMIL 16/14 1/0
References:
1. NFPA 70 National Electrical Code 2002 Table 610-14(a) 90° C, 60-minute, copper, 45° C ambient.
2. NFPA 70 National Electrical Code 2002. Table 250-122.
Wiring Size (AWG/KCMIL)
Model #
Rated
Current(A)
InputFuse
Time Delay
Input Fuse
Class
Inverse Time
Molded/Case
Circuit Breaker
Power Circuit
Wiring (1)
Control
Wiring
Ground
Copper (2)