Grove Published 02-21-2019, Control # 611-05 3-61
TMS9000-2 OPERATOR MANUAL OPERATING CONTROLS AND INDICATORS
3
4. Use an OK button to enable the limitation (note: alarms
will sound as the boom is at the limit).
5. Use the Right Arrow function once to highlight the
current outer radius (5). Use an OK button to accept the
current crane position to be the Limitation Value. The
Limitation Value should now be updated on the screen.
Note that the boom is now at the limitation, so alarm will
sound. The boom can now be moved away from the
current radius to cease the alarm.
6. The Outer Radius Limitation is now defined and
enabled.
Setting Working Radius by Value
To define and enable the Working Radius Limits Menu using
a “typed in” value as the limitation, the following steps can be
used:
1. Select the Working Radius Menu screen ((Figure 3-54))
on the Main Menu Screen.
2. Use the Right Arrow function to highlight the Switch
symbol (1).
3. Use an OK button to enable the limitation (Note: alarm
will sound if boom tip is above limit, when enabled).
4. Use the Right Arrow function to highlight the Maximum
Working Outside Radius Value (3). Use an OK button to
begin entering the value. Use the Up Arrow or the Down
Arrow or jog dial to change the value (in tenths) to the
desired boom elevation value. Use an OK button to
finish entering the value. Note that the boom may now
be at the limitation (depending on the value entered), so
alarms may be active. The boom can now be moved
away from the current boom elevation to cease the
alarm, if needed.
5. Use the same procedure to set the Inner Radius
Limitation.
Radius Limitation Disable Procedure
To disable an active Inner or Outer Radius Limitation, the
following steps are to be used (note that turning off the power
to the control system also disables the WRL limitations):
1. Select the Radius Limitation Screen ((Figure 3-55)) on
the Main Menu Screen.
2. Use the Left Arrow and/or Right Arrow function to
highlight the desired switch symbol (1 or 4).
3. Use an OK button to disable the limitation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS9000-2 Series and is the answer not in the manual?

Manitowoc Grove TMS9000-2 Series Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS9000-2 Series
CategoryConstruction Equipment
LanguageEnglish

Related product manuals