5-64 QX-830 Compact Industrial Scanner User’s Manual
Read Cycle
Maximum Element
Maximum Element
is the maximum bar (element) size before a reset. Value is in increments
of 0.01% of the scanner’s full scan width, not
increments of the framed scan width.
Scan Width Enhance
The scanner can adjust for Gain differences across the entire scan width. This is a useful
feature for long symbols that use most of the scan width available.
Note: This command is intended for applications in which symbols are three inches or
more from the scanner.
Disabled
The scanner will not adjust for scan width variation.
Enabled
The scanner will adjust for scan width variation.