5-76 QX-830 Compact Industrial Scanner User’s Manual
Symbologies
Separation Factor
Normal
No limits are placed on bar ratio accuracy.
High
The scanner will enforce a higher level of accuracy on bar ratios. If the symbol falls outside
this limit, it will be rejected.
Highest
The scanner will enforce the highest level of accuracy on bar ratios. If the symbol falls
outside this limit, it will be rejected.