QX-830 Compact Industrial Scanner User’s Manual A-13
Appendices
Matchcode
Matchcode
<K223,matchcode type,sequential matching,match start position,
match length,wild card,sequence on no read,sequence on mismatch>
Master Symbol Database Size <K224,number of master symbols>
New Master Pin <K225,status>
Sequence Step <K228,sequence step>
Master Symbol <K231,index,master symbol data>
Match Replace <K735,status,replacement string>
Mismatch Replace <K736,status,replacement string>
Diagnostics
High Temperature Threshold <K402,status,message>
Low Temperature Threshold <K403,status,message>
Counts (Read-only)
<K406> (returns: power-on,resets,
power-on saves,custom default
saves)
Hours Since Reset (Read-only) <K407> (returns: hours,minutes)
Service Message <K409,status,service message, threshold,resolution>
Laser Current Warning Message
<K411,laser high status,laser high message,laser low status,
laser low message>
User-Defined Name <K412,user-defined name>
Output Format
Format Extract <K740,output index,start location,length>
Format Insert <K741,output index,length,hex string>
Format Assign <K742,symbol number,status>
Output Format Status <K743,output format status>
Output Filter Configuration
<K744,filter number,symbology,length,wildcard,placeholder,
data,decode direction,database index>
Output Filter Enable <K745,number of filters>