A-24 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Postamble Characters
Response Timeout
LRC Status
ACK/NAK Options
RES-NAK Defaults
Polling Mode Options
RES-NAK Defaults
Autoconfiguration Daisy Chain
Serial Cmd: <K142,status,postamble character(s)>
Default: CR LF (0x0D 0x0A)
Options: 1 – 4 ASCII characters
Serial Cmd: <K143,response timeout>
Default: 5 (x10 ms = 50)
Options: 0 to 255 (x10 ms)
Serial Cmd: <K145,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K147,RES,REQ,STX,ETX,ACK,NAK>
RES: (Reset) 00 (disabled)
REQ: (Request) 00 (disabled)
STX: (Start of Text) 00 (disabled)
ETX: (End of Text) 00 (disabled)
ACK: (Acknowledge) 06
NAK: (Negative Acknowledge) 15
Serial Cmd: <K148,RES,REQ,STX,ETX,ACK,NAK>
RES: (Reset) 04
REQ: (Request) 05
STX: (Start of Text) 02
ETX: (End of Text) 03
ACK: (Acknowledge) 06
NAK: (Negative Acknowledge) 15
Serial Cmd: <K150DAISY>