A-32 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Minimum Gain
Maximum Gain
Symbol Detect Status / Transition Counter
Symbol Detect Status
Transition Counter
Scan Width Enhance
AGC Tracking
Laser Setup
Laser On/Off Status
Serial Cmd: <K504,AGC level,AGC mode,minimum gain,maximum gain>
Default: 0
(QX-830 model-dependent – see Microscan Product Pricing Catalog)
Options: 0 to 255
Serial Cmd: <K504,AGC level,AGC mode,minimum gain,maximum gain>
Default:
255 (QX-830 model-dependent – see Microscan Product Pricing Catalog)
Options: 0 to 255
Serial Cmd: <K505,symbol detect status,transition counter>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K505,symbol detect status,transition counter>
Default: 14
Options: 1 to 255
Serial Cmd: <K511,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K520,tracking value>
Default:
40 (QX-830 model-dependent – see Microscan Product Pricing Catalog)
Options: 5 to 127
Serial Cmd: <K700,laser on/off status,laser framing status,laser on position,laser off
position,laser power>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled

Table of Contents