QX-830 Compact Industrial Scanner User’s Manual A-43
Appendices
Format UPC-E as UPC-A (UPC/EAN)
Code 128/EAN 128
Fixed Symbol Length Status (Code 128/EAN 128)
Fixed Symbol Length (Code 128/EAN 128)
EAN 128 Status (Code 128/EAN 128)
Serial Cmd: <K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd:
<
K474,status
,fixed symbol length status,fixed symbol length,EAN 128 status
,
output format,application record separator status,application record separator
character,application record brackets,application record padding
,separation
factor>
Default: 3 = Both Standard and Edge-to-Edge
Options: 0 = Disabled
1 = Standard
2 = Edge-to-Edge
3 = Both Standard and Edge-to-Edge
Serial Cmd:
<
K474,
status,
fixed symbol length status
,fixed symbol length,EAN 128 status
,
output format,application record separator status,application record separator
character,application record brackets,application record padding
,separation
factor>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K474,status,fixed symbol length status,fixed symbol length,EAN 128
status,output format,application record separator status,application record
separator character,application record brackets,application record padding
,
separation
factor>
Default: 10
Options: 1 to 128
Serial Cmd:
<
K474,
status,fixed symbol length status,fixed symbol length,
EAN 128 status
,
output format,application record separator status,application record separator
character,application record brackets,application record padding
,separation
factor>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled 2 = Required