QX-830 Compact Industrial Scanner User’s Manual A-45
Appendices
Separation Factor
Code 93
Fixed Symbol Length Status (Code 93)
Symbol Length (Code 93)
PDF417
Scan Line Limit
Serial Cmd: <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,
output format,application record separator status,application record separator
character,application record brackets,application record padding,separation
factor>
Default: 0 = Normal
Options: 0 = Normal
1 = High
2 = Highest
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 3 = Both Standard and Edge-to-Edge
Options: 0 = Disabled
1 = Standard
2 = Edge-to-Edge
3 = Both Standard and Edge-to-Edge
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 10
Options: 1 to 128
Serial Cmd: <K476,status,scan line limit,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K476,status,scan line limit,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 65535 (Disabled)
Options: 1 to 65535