QX-830 Compact Industrial Scanner User’s Manual A-47
Appendices
Minimum Bars (Pharmacode)
Bar Width Status (Pharmacode)
Direction (Pharmacode)
Fixed Threshold Value (Pharmacode)
GS1 DataBar (RSS)
DataBar Omnidirectional (RSS-14)
DataBar Limited (RSS Limited)
DataBar Expanded (RSS Expanded)
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 4
Options: 1 to 16
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Mixed
Options: 0 = Mixed
1 = All Narrow
2 = All Wide
3 = Fixed Threshold
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Forward
Options: 0 = Forward 1 = Reverse
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 400
Options: 1 to 65535
Serial Cmd: <K482,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K483,status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K484,status,fixed symbol length status,fixed symbol length>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled