A-54 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Input 1
Active State
Green Flash LED
Green Flash Mode
Green Flash Duration
Status Indicators
Bar Graph
Serial Cmd: <K730,status,active state>
Default: 0 = Disabled
Options: 0 = Disabled
1 = Reset Counts
2 = Unlatch Output
Serial Cmd: <K730,status,active state>
Default: 0 = Active Open
Options: 0 = Active Open 1 = Active Closed
Serial Cmd: <K750,green flash mode,unused,green flash duration>
Default: 1 = Good Read
Options: 0 = Disabled
1 = Good Read
2 = Static Presentation
3 = Match
4 = Mismatch
5 = Strobe
Serial Cmd: <K750,green flash mode,unused,green flash duration>
Default: 100 (1 second)
Options: 0 to 65535 (in 10 ms increments)
Serial Cmd: <K751,status,bar graph,I/O 1,I/O 2>
Default: 1 = PHY Activity
Options: 0 = Disabled
1 = PHY Activity
2 = Protocol Activity
Serial Cmd: <K751,status,bar graph,I/O 1,I/O 2>
Default: 1 = Read Rate / Good Read
Options: 0 = Disabled
1 = Read Rate / Good Read

Table of Contents