A-64 QX-830 Compact Industrial Scanner User’s Manual
Serial Commands
Power-On Saves
Custom Default Saves
Hours Since Reset (Read-only)
Hours
Minutes
Service Message
Service Message
Threshold
Resolution
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>
16-bit counter that increments when a scanner setting is saved for power-on
(<Z> command).
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>
16-bit counter that increments when a scanner setting is saved to the customer
parameter section of flash memory (<Zc> command).
Serial Cmd: <K407,hours,minutes>
16-bit counter (0 to 65535)
Serial Cmd: <K407,hours,minutes>
16-bit counter (0 to 60)
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: SERVICE
Options: Any valid ASCII string up to 128 characters
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 300 (5 minutes)
Options: 1 to 65535
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 0 = Seconds
Options: 0 = Seconds 1 = Minutes