Chapter 4 Maintenance
4-17
1
2
2
4
5
6
6
Replace the waste ink tank .
(1) Prepare a new waste ink tank (SPA-0277).
(2) Insert the waste ink tank by holding a handle
of the tank.
7
Press the key.
The ink discharging amount that is controlled by
the machine is reset and the message is
cancelled.
Replacing the waste ink tank before the waste
ink tank confirmation message is displayed
If you replace the waste ink tank before the waste ink tank
confirmation message is displayed (before the 2L tank is
80% (1.6L) full) follow the same procedure as described in
the previous section.
1
Perform steps 2 through 7 in "Replace the
waste ink tank with another" ( P.4-16) to
empty the waste ink tank.
Refilling antifreeze
mixed water
To cool the LED UV unit, put antifreeze mixed water into
the cooling water tank in the cooling device.
Note on refill
Note on antifreeze mixed water
Waste ink is equivalent to waste oil of industrial
waste. Request an industrial waste disposal
company for disposal of waste ink.
New waste ink
tank
When only water is supplied to the cooling water
tank without antifreeze liquid, it may damage the
UV unit by freeze.
When only antifreeze liquid is supplied to the
cooling water tank without water, the machine
does not work properly, and may cause an error.
If water in the cooling water tank frequently
becomes insufficient, contact a distributor in your
district or our office.
Dispose of the waste water mixed with antifreeze
liquid pursuant to the regulations of your district.
To make mixed water, be sure to use the potable
water meeting one of the following conditions:
Calcium content:
1 mg/100 ml (10 mg/L) or less
Hardness : 60 mg/L or less
Distilled water (Purified water)
Water and antifreeze liquid compound ratio should
be 2(water) to 1(Antifreeze liquid).
Or use our specialized antifreeze mixed water
(SPC-0783).
Use it within one week when you make mixed
water. The mixed water that one week or more
passed after it makes it is never used for this
machine regardless of use/unused.
Moreover, do not add to the mixed water newly
made.
Cooling device

Table of Contents

Other manuals for MIMAKI UJF-7151 plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI UJF-7151 plus and is the answer not in the manual?

MIMAKI UJF-7151 plus Specifications

General IconGeneral
BrandMIMAKI
ModelUJF-7151 plus
CategoryPrinter
LanguageEnglish

Related product manuals