FrameMaker Ver.5.5E(PC) Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
05.03.01
D-19
(8) Removal of the Scanner Drive Cables
1. Remove the Original Glass.
2. Remove the Scanner.
3. Remove the Left Upper Cover and Left IR Cover.
4011D042AA
4. Unhook the spring at the end of the cable from
the front hook and remove the cable guide.
5. Unhook the spring at the end of the cable from
the rear hook.
Front
Rear
Cable
Guide
6. Remove one screw, unplug one connector, and
remove the Original Size Detecting Sensor.
Option for the inch areas
4011D043AA
7. Remove the cover.
See step 2 of "(2) Removal of the CCD Unit" of "2-
5. OPTICAL SECTION."
8. Remove four screws and the Reinforcement
Bracket.
4011D044AD
4011D045AA
9. Snap off one retaining ring E type and remove
one mounting screw from the front pulley and
slide the pulley to the rear.
10. Snap off one retaining ring E type and remove
one mounting screw from the rear pulley and
slide the pulley to the front.
11. Remove the Scanner Drive Cable, hook end first.
4011D046AA