98
SEND
SEND:
Sends data to a programmable controller on another station.
*2
RECV:
Reads data received from a programmable controller on another station.
(For main program)
*2
RECVS:
Reads data received from a programmable controller on another station.
(For interrupt program)
*2
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
• RCPU
•LCPU
•QnACPU
• Interface board for
a personal
computer*
4
RECV
• CC-Link IE
Controller
Network
•QCPU
RECVS
ZNRD
Reads data from devices of a programmable controller on another
station. (In units of words)
*2
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
• RCPU
•LCPU
•QnACPU
• AnUCPU*
5
•AnACPU
• AnNCPU
ZNWR
Writes data to devices of a programmable controller on another station.
(In units of words)
*2
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
• RCPU
•LCPU
•QnACPU
• AnUCPU*
5
•AnACPU
• AnNCPU
RRUN
Instructs a programmable controller on another station to run remotely.
*2
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
• RCPU
•LCPU
Instruction
*1
Description
Target (another station)
Target network
Target station
type
Command
SEND RECV
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
CPU module CPU moduleCC-Link IE Controller
Network module
CC-Link IE Controller
Network module
CPU module CPU moduleCC-Link IE Controller
Network module
CC-Link IE Controller
Network module
Command
SEND
RECVS
I50
Interrupt
program
Command
ZNRD
Channel 1
(Fixed)
Word device
2594
CPU module
CPU module
CC-Link IE Controller
Network module
Network module
2594
Word device
Command
ZNWR
Channel 2
(Fixed)
Word device
361
CPU module CPU moduleCC-Link IE Controller
Network module
Network module
Command
RRUN
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
RUNRUN
CPU module CPU moduleCC-Link IE Controller
Network module
Network module

Table of Contents

Other manuals for Mitsubishi Electric MELSEC-Q Series

Related product manuals