CHAPTER 9 DEDICATED INSTRUCTIONS
9
9.11 Z.RECVS (Data Reception from Programmable Controllers on Other Stations)
9.11 Z.RECVS (Data Reception from Programmable
Controllers on Other Stations)
This instruction reads data received from a programmable controller on another station. (For interrupt program)
*1 If the originating station is a Basic model QCPU (function version B or later) or Universal model QCPU, " " (double
quotation) of the first argument can be omitted.
(1) Setting data
*1 Local devices and file registers for each program cannot be used as devices in setting data.
Settin
g data
Available devices
Internal device
(System, User)
File
register
R, ZR
Link direct device
J\
Intelligent
function
module device
U\G
Index
register
Zn
Constant
Others
Bit Word Bit Word K, H $
(S1) — —
(D1) — —
(D2) —
Setting data
*1
Description Data type
"Un"/Un
Start I/O number of the own station's CC-Link IE Controller Network module
(00 to FE
H
: The higher two digits of the 3-digit I/O number)
String/
Binary 16 bits
(S1)
Start device of the own station that stores control data
( Page 422, Section 9.11 (2))
Device name
(D1)
Start device of the own station that stores receive data
(A contiguous area for the receive data length is required.)
(D2) Dummy Bit
Z.RECVS
"Un"
*1
(S1) (D1) (D2)
Z.RECVS
Start contact
[Instruction format][Execution condition][Instruction symbol]