6.9 Routing Parameters
Set a relay station in the own network to transmit data to another network.
Set the routing parameters under one of the following conditions.
• When using the dedicated instruction to perform transient transmission to a different network ( Page
324, CHAPTER 9)
• When using the IP packet transfer function ( Page 106, Section 4.3)
For the routing function, refer to the following.
Page 103, Section 4.2.3
● Up to 64 routing information settings are available for one programmable controller.
● Setting the same target network No. is not allowed.
1. Open the "Setting the Ethernet/CC IE/MELSECNET Routing Information" window in the
programming tool.
Project window [Parameter] [Network Parameter] [Ethernet/CC IE/MELSECNET]
button
2. Configure settings with reference to the description below.
3. Click the button.
Item Description
Target Network No.
Set a network No. of another network.
(Setting range: 1 to 239, Default: None)
Relay Network No.
Set the own network No.
(Setting range: 1 to 239, Default: None)
Relay Station No.
Set the station No. of the relay station in the own network.
(Setting range for Universal model QCPU: 0 to 120, Default: None)
(Setting range for other than Universal model QCPU: 0 to 64, Default: None)