100
(b) Transient transmission range of link dedicated instructions
• Single network system
Communication is available with all of the stations in the network.
Note that the specification range of the target station No. varies depending on the CPU module on the own
station.
: Available, ×: N/A
*1 When the own station is in a multiple CPU system, connecting a peripheral to a Universal model QCPU enables access
to station No.65 to 120 via a CC-Link IE Controller Network module controlled by a QCPU other than Universal model
QCPU.
• Multi-network system
In a multi-network system, using the routing function allows communication with a station located in the
eighth farthest network. ( Page 103, Section 4.2.3)
By "Communication Test" in a programming tool, whether routing of transient transmission can be correctly performed
between the own station and a communication destination can be checked. ( Page 174, Section 5.7.1)
Target station
Own station (request source)
Universal model QCPU Other than Universal model QCPU
Station No.1 to 64
Station No.65 to 120
×
*1
(Relay station 1)
Network No.1
Network No.9
Network No.2 Network No.3
Network No.4
Network No.6
Network No.7
Network No.5
Network No.8
(Relay station 4)
1NS2
CPU
module
1MP1
9NS2
9NS3
8NS4
1NS3 1NS4 2NS3
8NS3
3MP1
2M
P1
9MP18NS2
(Relay station 2)
2NS23NS3
(Relay station 7)
8MP17NS2
(Relay station 3)
3NS24MP1
4NS25MP1
(Relay station 5)
5NS26MP1
(Relay station 6)
7MP16NS2
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module
CPU
module