220
Program example of when specifying an R in an access instruction to the file register
Switch the block No. by specifying it in the RSET instruction.
Access to the file register can be specified with R or ZR.
If an access instruction to the file register is specified with an R,
Block switching in units of 32K points is required.
The sequence program execution speed is fast.
The sequence program capacity is small.
RSET K0
MOV R0D0
RSET K1
MOV D1
RSET K3
MOV D2
R0
R32767
LW0
LWD100
LW19230
LW1FFFF
R0
R0
R32767
R32767
R32767
R4656
R20736
R0
R20736
R4656
CC-Link IE Controller
Network module
CPU module
Block 0
Block 1
Block 2
Block 3
Send
request