308
(d) Cyclic transmission restart of own station
1. Turn Link startup (own station) (SB0000) ON.
2. When the CC-Link IE Controller Network module accepts the request, Cyclic transmission start
accept status (own station) (SB004C) is turned ON.
3. When the cyclic transmission restart is completed, Cyclic transmission start completion status
(own station) (SB004D) is turned ON.
4. If the cyclic transmission restart is completed abnormally, an error code will be stored in Data
linking start status (own station) (SW004D).
5. Turn Link startup (own station) (SB0000) OFF.
No. Description No. Description
SB0000 Link startup (own station)
—
SB0001 Link stop (own station)
SB004C
Cyclic transmission start accept status (own
station)
SB004D
Cyclic transmission start completion status
(own station)
SW004D Data linking start status (own station)
SB004E
Cyclic transmission stop accept status (own
station)
—
SB004F
Cyclic transmission stop completion status
(own station)
SW004F Data linking stop status (own station)