447
CHAPTER 9 DEDICATED INSTRUCTIONS
9
9.14 Z(P).RRUN (Remote RUN)
(d) Operation in RRUN instruction execution
• Operation of the own station
(e) RRUN instruction execution timing
With Z.RRUN, processing is executed one after another while the start contact is ON.
With ZP.RRUN, processing is performed one time only when the start contact turns ON from OFF.
• When completed normally
Program of
own station
Completion device
of own station (D1)
Completion status
indication device
((D1)+1)
RRUN instruction
RRUN instruction execution RRUN instruction execution
completed
Start contact
OFF
OFF
OFF
ON
ON
ON
END
processing
END
processing
END
processing
END
processing
When failed
Normal completion
1 scan
1 scan
RRUN
Sequence scan
Start contact
Own station CPU
Target station CPU
Remote RUN
CC-Link IE Controller
Network module
Network module
OFF
Completion device
(Device specified in (D1))
Completion status indication
device (Device of (D1)+1)
Sequence scan
Stopped Stopped
END0 END0
Channel 1
END0 END0 END0
END0 END0 END0