85
CHAPTER 4 FUNCTIONS
4
4.1 Cyclic Transmission Function
4.1.9 Increase of send points by mounting multiple CC-Link IE Controller Network modules of the same
network No.
(1) Setting network parameters
Set the same network No. to multiple CC-Link IE Controller Network modules in the network setting.
The setting is explained using the following system configuration, where two CC-Link IE Controller Network
modules are mounted.
(a) Network setting
Configure the network setting as shown below.
(b) Network range assignment
Set each station's send range in LB/LW in "LB/LW Setting" of "Network Range Assignment" of the control
station. ( Page 185, Section 6.3.1)
The setting example indicates
this part of the configuration.
Control station
1M
P
1
Normal station
1N
S
2
Normal station
1N
S
3
Normal station
1N
S
4
Normal station
1N
S
5
Set the same network No.
Set a unique station number for each station.
The same station No. cannot be set to
multiple stations.
Set one station as the control station.
Multiple control stations cannot be configured.