MC2000 – Assembly Instruction Manual
30
Connecting control panel wiring
Connecting drive command box
Safety
1. Connect the cables in the control panel ac-
cording to the electrical diagram.
Do not cut the cables too short.
Unload the cables with cable tie.
Import
ant! Make sure there is no lead
connected to terminal input 15 on the
PLC! Impulse function!
Use the approved drive command box from
Motal
a Hissar (with emergency stop).
Note! For your own safety and that of other
pers
ons, disconnect the control voltage for
the call buttons, connected to terminals X1/
47 and X1/48. See the electrical drawings.
1. Connect the emergency stop to block X1/3
and X1/
10 in the controlpanel. Important!
This is the same terminals where the
platform safety contacts will be con-
nected later. The command box shall be
di
sconnected before connect the plat-
form safety leads.
2. Connect the lift drive wires. Connect the
sup
ply to terminal X1/24V, upwards drive to
X1/42 and downwards drive to X1/41. See
the electrical drawings.