43
MC2000 – Assembly Instruction Manual 2011-10
Lock arms
Highspeed contact and magnet
5. Run the lift to an exact position on each
floor and fit the lock arm. When the lift is on
a certain floor, the roller of the lock arm
should be in the centre of the ramp. Note!
There is an exception for the bottom and
top floors: there, the lock arm should be fit-
ted so that, when the lift reaches the floor,
the roller has just reached the flat part of
the ramp.
6. Adjust the length of the lock wires by cut-
ting the outer cover so that it reaches the
lock arm. Let the inner cover run a short
distance through the lock arm sleeve. Pull it
down and fasten excessive wire in the re-
cess of the arm.
1. Adjust the distance of the floor counting
contact 61: (if any) and highspeed contact
to 7 mm from the lift well wall.
2. Fasten the highspeed contact magnet (1)
at every floor. Adjust the magnet so it
starts and ends 50 mm from the floor in
question.