Beam Timer - Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments of 100
ms). A value of 0 sets the reader to stay on indefinitely (default -15000).
Linear Security Level - Sets the number of times a bar code is read to confirm an accurate decode.
- Security Short or Codabar - Two times read redundancy if short bar code or Codabar.
- Security All Twice - Two times read redundancy for all bar codes (default).
- Security Long and Short - Two times read redundancy for long bar codes, three times for short bar codes.
- Security All Thrice - Three times read redundancy for all bar codes.
Picklist - Allows the imager to decode only the bar code that is directly under the cross-hair/reticle (+) part of the
pattern. This feature is useful in applications where multiple bar codes may appear in the field of view during a
decode session and only one of them is targeted for decode.
- Disable – Disables Picklist mode. Any bar code within the field of view can be decoded (default).
- Enabled – Enables Picklist mode. Only the bar code in the center of the image is decoded.
- Reticle - Enables the Picklist mode so that only the bar code that is directly under the cross-hair (reticle) is
decoded. This is useful when used in conjunction with the static and dynamic reticle viewfinder modes. (Scan
Module Only)
Illumination mode - Turns camera illumination on and off. This option is only available when camera is selected
in the Barcode input Scanner selection option.
- On - Illumination is on.
- Off - Illumination is off (default).
Inverse 1D Mode - This parameter allows the user to select decoding on inverse 1D bar codes.
- Disable - Disables decoding of inverse 1D bar codes (default).
- Enable - Enables decoding of only inverse 1D bar codes.
- Auto - Allows decoding of both twice positive and inverse 1D bar codes.
Scan Params
Allows the configuration of Code ID and decode feedback options.
Code ID Type - A Code ID character identifies the code type of a scanned bar code. This is useful when the
reader is decoding more than one code type. Select a code ID character to insert between the prefix and the
decoded symbol.
- Code ID Type None - No prefix (default).
- Code ID Type Aim - A standards based three character prefix.
- Code ID Type Symbol - A Symbol defined single character prefix.
Note: Not all ringtones are fully supported as decode tones and those of longer length may be truncated
when used as a decode tone. The recommendation is to test the selected tone for operation before
deployment to a customer site.
Decode Audio Feedback - Select an audio tone to sound upon a good decode.
Decode Haptic Feedback - Enable the device to vibrate upon a good decode (default - enabled).
MSR Input
Use MSR Input options to configure the MSR Input Plug-in for the profile.
Enabled — Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled.
Keystroke Output
Use to configure the Keystroke Output Plug-in for the profile.
Enabled — Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is enabled (default
- enabled).
DataWedge Configuration | 69
MN000116A02-A | May 2015

Table of Contents

Other manuals for Motorola MC67

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MC67 and is the answer not in the manual?

Motorola MC67 Specifications

General IconGeneral
BrandMotorola
ModelMC67
CategoryHandhelds
LanguageEnglish

Related product manuals