5 - 68 WiNG 5.5 Access Point System Reference Guide
19. Select Add to create a new manual session, Edit to modify an existing session configuration or Delete to remove a
selected manual session.
Figure 5-37 Network - L2TPv3 screen, Add T2TP Peer Configuration
20. Set the following session parameters:
Local Session ID Displays the numeric identifier assigned to each listed tunnel session. This is the
pseudowire ID for the session. This pseudowire ID is sent in a session establishment
message to the L2TP peer.
MTU Displays each sessions’s maximum transmission unit (MTU). The MTU is the size (in bytes)
of the largest protocol data unit the layer can pass between tunnel peers in this session.
A larger MTU means processing fewer packets for the same amount of data.
Name Lists the name assigned to each listed manual session.
Remote Session ID Lists the remote session ID passed in the establishment of the tunnel session.
Name Define a 31 character maximum name for this tunnel session. Each session name
represents a single data stream.

Table of Contents