Network configuration 7 - 11
6. Select OK to save the updates to the L2TP V3 Policy Details. Select Reset to revert to the last saved configuration.
Reconnect Attempts Use the spinner control to set a value (from 0 - 250) representing the maximum number of
reconnection attempts initiated to reestablish the tunnel. The default interval is 0.
Reconnect Interval Define an interval in either Seconds (1 - 3,600), Minutes (1 -60) or Hours (1) between two
successive reconnection attempts. The default setting is 2 minutes.
Retry Count Use the spinner control to define how many retransmission attempts are made before
determining a target tunnel peer is not reachable. The available range is from 1 - 10, with a
default value of 5.
Retry Time Out Use the spinner control to define the interval (in seconds) before initiating a retransmission
of a L2TP V3 signaling message. The available range is from 1 - 250, with a default value of 5.
Rx Window Size Specify the number of packets that can be received without sending an acknowledgement.
The available range is from 1 - 15, with a default setting of 10.
Tx Window Size Specify the number of packets that can be transmitted without receiving an
acknowledgement. The available range is from 1 - 15, with a default setting of 10.
Failover Delay Specify the wait time (in seconds) before re-establishing a failed tunnel.The available
duration is 5 - 60 seconds or 1 minute with a default setting of 5 seconds.
Force L2 Path
Recovery
Select to enable forcing the discovery of servers, gateways and other networks behind a
L2TPV3 tunnel when a tunnel is being established or when a failed tunnel is being
reestablished.