8 Settings via the MICT
136 Rev. 03/2019
Error Description
Output board identification failed
due to incompatible hardware.
The identification of the output board failed due to
incompatible hardware. Restart the ignition controller. If
the error occurs again after restarting the device, please
contact MOTORTECH.
Output board identification failed
due to missing data.
The identification of the output board failed due to
missing data. Restart the ignition controller. If the error
occurs again after restarting the device, please contact
MOTORTECH.
Output board identification failed
due to unknown error number.
The identification of the output board failed due to
unknown error number. Characteristic data of the output
board could not be read, they are defective or do not
match the device. Restart the ignition controller. If the
error occurs again after restarting the device, please
contact MOTORTECH.
Output board identification failed
due to unknown hardware.
The identification of the output board failed due to
unknown hardware. Characteristic data of the output
board could not be read, they are defective or do not
match the device. Restart the ignition controller. If the
error occurs again after restarting the device, please
contact MOTORTECH.
Power failure detected on output
Anumber/Bnumber.
Power supply fault in output board caused by output
Anumber/Bnumber was detected. Restart the ignition
controller. If the error occurs again after restarting the
device, please contact MOTORTECH.
Power output (x W) exceeded error
threshold limit (y W) at a supply
voltage of z V.
The power output (x W) exceeded failure threshold (
W)
at a supply voltage of z V.
Power output (x W) exceeded
permanent limit (y W) at a supply
voltage of z V.
The power output (x W) exceeded warning threshold limit
(y W) for longer than three minutes at a supply voltage of
z V .
Self test aborted because pickup
signals have been detected on
pickup input PUnumber.
Self test aborted because pickup signals have been
detected on pickup input PUnumber. Self test can only be
carried out when engine is at a standstill (see Self Test on
page 77).
Potential causes:
– Interference coupling on pickup signal
– Engine was started