Handling the printer VJ-1628X OPERATION MANUAL
168 4.2 Media
4. Sets up Initial Adjust Change.
a. Press the [+] key or [–] key on Operation panel to select “PF2: Initial Change”.
b. Press the [Enter] key on Operation panel.
• “Init.: 250.0/250 mm” is displayed on Operation panel.
c. Press the [+] key or [-] key on Operation panel and enter the measured value in Step 3.
d. Press the [Enter] key on Operation panel.
• The initial adjustment value is saved.
• “PF2: Initial Change” is displayed on Operation panel.
5. Performs Confirm Print.
a. Press the [+] key or [–] key on Operation panel to select "PF3: Confirm Print".
b. Press the [Enter] key on Operation panel.
• "Feed Length: 250 mm" is displayed on Operation panel.
The length of media that is fed (feeding length) for confirmation adjustment printing is normally set at 250 mm.
If you increase the feeding length, the accuracy of the Media feed compensation improves.
To change the feeding length, press the [+] key or [-] key on Operation panel and change the set value.
c. Press the [Enter] key on Operation panel.
• “Printing” is displayed on Operation panel.
• Starts confirmation adjustment printing.
• When the Confirm Print is complete, the printer enters Normal.
No. Name
1 Feed Length
2 Media feeding direction