Configure Switching
154
XS708T, XS712Tv2, and XS716T Smart Managed Pro Switch User Manual
6. Select one or more interfaces by taking one of the following actions:
To configure a single interface, select the check box associated with the port, or type
the port number in the Go To Interface field and click the Go button.
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
To configure all interfaces with the same settings, select the check box in the heading
row.
7. From the STP Status menu, select the option to enable or disable spanning tree
administrative mode associated with the port or port channel.
The possible values are Enable and Disable. The default value is Enable.
8. From the Fast Link menu, select whether the specified port is an edge port within the CST.
The possible values are Enable and Disable. The default value is Enable.
9. From the BPDU Forwarding menu, configure BPDU forwarding.
The possible values are Enable and Disable. The default value is Disable. When BPDU
forwarding is enabled, the switch forwards the BPDU traffic arriving on this port when
STP is disabled on this port.
10. From the Auto Edge menu, specify if the port is allowed to become an edge port if it does
not detect BPDUs for some duration.
The possible values are Enable and Disable. The default value is Disable.
11. In the Path Cost field, set the path cost to a new value for the specified port in the common
and internal spanning tree.
Specify a value in the range of 0 to 200000000. The default is 0. When the path cost is set
to 0, the value is updated with the external path cost from a received STP packet.
12. In the Priority field, specify the priority for a particular port within the CST.
The port priority is set in multiples of 16. For example if you attempt to set the priority to
any value between 0 and 15, it is set to 0. If you try to set it to any value between 16 and
(2*16 – 1), it is set to 16, and so on. The range is 0 to 240. The default value is 128.
13. In the External Port Path Cost field, set the external path cost to a new value for the
specified port in the spanning tree.
The value range is 0 to 200000000. The default is 0.
14. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
15. To refresh the page with the latest information about the switch, click the Update button.

Table of Contents

Other manuals for NETGEAR XS708T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR XS708T and is the answer not in the manual?

NETGEAR XS708T Specifications

General IconGeneral
Switch typeManaged
Switch layerL2+/L3
Quality of Service (QoS) supportYes
USB 2.0 ports quantity1
SFP+ module slots quantity2
Installed SFP modules quantity-
Basic switching RJ-45 Ethernet ports type10G Ethernet (100/1000/10000)
Basic switching RJ-45 Ethernet ports quantity8
CertificationCE, FCC Cl. A, VCCI Cl. A, Cl. A EN 55022 (CISPR 22), Cl. A C-Tick, EN 55024, CCC
Product colorBlack
LED indicatorsActivity, Link, Power
Number of fans1 fan(s)
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3an, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Virtual LAN featuresPrivate VLAN, Protocol-based VLAN
Cable types supportedCat5e, Cat6, Cat6a, Cat7
Copper ethernet cabling technology10GBASE-T
Noise level29.1 dB
Flash memory256 MB
Internal memory512 MB
Processor frequency600 MHz
Mean time between failures (MTBF)276832 h
Jumbo frames9000
Latency (10 Gbps)3.012 µs
MAC address table16000 entries
Packet buffer memory2 MB
Number of static routes32
DHCP featuresDHCP server, DHCP client
Security algorithms802.1x RADIUS
Access Control List (ACL) rules100
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (max)96 W
Operating altitude0 - 3000 m
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2980 g