EasyManuals Logo

NETGEAR XS708T User Manual

NETGEAR XS708T
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
Manage Device Security
267
XS708T, XS712Tv2, and XS716T Smart Managed Pro Switch User Manual
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see Change the Default IP Address of the
Switch on page 10.
The login window opens.
4. Enter the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select Security > Management Security > RADIUS > Global Configuration.
The Current Server IP Address field is blank if no servers are configured (see Configure a
RADIUS Authentication Server on the Switch on page 268). The switch supports up to
three RADIUS servers. If more than one RADIUS server is configured, the current server
is the server configured as the primary server. If no servers are configured as the primary
server, the current server is the most recently added RADIUS server.
6. In the Max Number of Retransmits field, specify the maximum number of times a request
packet is retransmitted to the RADIUS server.
The valid range is from 1 to 15. The default value is 4.
Consider the maximum delay time when you are configuring RADIUS maximum
retransmit and RADIUS time-out values. If multiple RADIUS servers are configured, the
maximum retransmit period on each server runs out before the next server is attempted.
A retransmit does not occur until the configured time-out period on that server passes
without a response from the RADIUS server. Therefore, the maximum delay in receiving
a response from the RADIUS application equals the retransmit time x time-out period for
all configured servers. If the RADIUS request was generated by a user login attempt, all
user interfaces are blocked until the RADIUS application returns a response.
7. In the Timeout Duration field, specify the time-out value, in seconds, for request
retransmissions.
The valid range is from 1 to 30. The default value is 5.
Consider the maximum delay time when you are configuring RADIUS maximum
retransmit and RADIUS time-out values. If multiple RADIUS servers are configured, the
maximum retransmit period on each server runs out before the next server is attempted.
A retransmit does not occur until the configured time-out period on that server passes
without a response from the RADIUS server. Therefore, the maximum delay in receiving

Table of Contents

Other manuals for NETGEAR XS708T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR XS708T and is the answer not in the manual?

NETGEAR XS708T Specifications

General IconGeneral
Switch typeManaged
Switch layerL2+/L3
Quality of Service (QoS) supportYes
USB 2.0 ports quantity1
SFP+ module slots quantity2
Installed SFP modules quantity-
Basic switching RJ-45 Ethernet ports type10G Ethernet (100/1000/10000)
Basic switching RJ-45 Ethernet ports quantity8
CertificationCE, FCC Cl. A, VCCI Cl. A, Cl. A EN 55022 (CISPR 22), Cl. A C-Tick, EN 55024, CCC
Product colorBlack
LED indicatorsActivity, Link, Power
Number of fans1 fan(s)
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3an, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Virtual LAN featuresPrivate VLAN, Protocol-based VLAN
Cable types supportedCat5e, Cat6, Cat6a, Cat7
Copper ethernet cabling technology10GBASE-T
Noise level29.1 dB
Flash memory256 MB
Internal memory512 MB
Processor frequency600 MHz
Mean time between failures (MTBF)276832 h
Jumbo frames9000
Latency (10 Gbps)3.012 µs
MAC address table16000 entries
Packet buffer memory2 MB
Number of static routes32
DHCP featuresDHCP server, DHCP client
Security algorithms802.1x RADIUS
Access Control List (ACL) rules100
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (max)96 W
Operating altitude0 - 3000 m
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2980 g

Related product manuals