Configure System Information
45
XS708T, XS712Tv2, and XS716T Smart Managed Pro Switch User Manual
4. Enter the switch’s password in the Password field.
The default password is password.
The System Information page displays.
5. Select System > Management > Time > Time Configuration.
The Time Configuration page displays.
6. Next to Clock Source, select the SNTP radio button.
The page refreshes and displays the SNTP Global Configuration section and the SNTP
Global Status section.
The default is SNTP. The local clock can be set to SNTP only if the following two
conditions are met:
The SNTP server is configured.
The SNTP last attempt status is successful.
7. Next to Client Mode, select the mode of operation of the SNTP client:
Disable. SNTP is not operational. No SNTP requests are sent from the client nor are
any incoming SNTP messages processed.
Unicast. SNTP operates in a point-to-point fashion. A unicast client sends a request
to a designated server at its unicast address and expects a reply from which it can
determine the time and, optionally, the round-trip delay and local clock offset relative
to the server.
Broadcast. SNTP operates in the same manner as multicast mode but uses a local
broadcast address instead of a multicast address. The broadcast address provides a
single-subnet scope while a multicast address provides an Internet-wide scope.
The default value is Disable.
8. If the SNTP client mode is Unicast, use the SNTP Server Configuration page to add the IP
address or DNS name of one or more SNTP servers for the switch to poll.
For more information, see Configure an SNTP Server on page 50.
9. In the Port field, specify the local UDP port that the SNTP client receives server packets on.
The allowed range is 1025 to 65535 and 123. The default value is 123. When the default
value is configured, the actual client port value used in SNTP packets is assigned by the
OS.
10. In the Unicast Poll Interval field, specify the number of seconds between unicast poll
requests expressed as a power of 2. to The allowed range is 6 to 10. The default value is 6.
11. In the Broadcast Poll Interval field, specify the number of seconds between broadcast poll
requests expressed as a power of 2.
Broadcasts received prior to the expiry of this interval are discarded. The allowed range is
6 to 10. The default value is 6.
12. In the Unicast Poll Timeout field, specify the number of seconds to wait for an SNTP
response to a unicast poll request.

Table of Contents

Other manuals for NETGEAR XS708T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR XS708T and is the answer not in the manual?

NETGEAR XS708T Specifications

General IconGeneral
Switch typeManaged
Switch layerL2+/L3
Quality of Service (QoS) supportYes
USB 2.0 ports quantity1
SFP+ module slots quantity2
Installed SFP modules quantity-
Basic switching RJ-45 Ethernet ports type10G Ethernet (100/1000/10000)
Basic switching RJ-45 Ethernet ports quantity8
CertificationCE, FCC Cl. A, VCCI Cl. A, Cl. A EN 55022 (CISPR 22), Cl. A C-Tick, EN 55024, CCC
Product colorBlack
LED indicatorsActivity, Link, Power
Number of fans1 fan(s)
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1ab, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3an, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Virtual LAN featuresPrivate VLAN, Protocol-based VLAN
Cable types supportedCat5e, Cat6, Cat6a, Cat7
Copper ethernet cabling technology10GBASE-T
Noise level29.1 dB
Flash memory256 MB
Internal memory512 MB
Processor frequency600 MHz
Mean time between failures (MTBF)276832 h
Jumbo frames9000
Latency (10 Gbps)3.012 µs
MAC address table16000 entries
Packet buffer memory2 MB
Number of static routes32
DHCP featuresDHCP server, DHCP client
Security algorithms802.1x RADIUS
Access Control List (ACL) rules100
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (max)96 W
Operating altitude0 - 3000 m
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2980 g